Mv 18/30kv Copper Conductor XLPE Insulated Steel Tape Armored Power Cable

November 16, 2018

Model NO.: YJV22, YJV23
Certification: ISO, CCC
Model: Yjv22,Yjv23
Brand: Jytop
Trademark: JYTOP
Transport Package: Packed in Reels
Specification: any Third party Pre-shipment inspection
Origin: Zhengzhou, China
HS Code: 8544601200
Model NO.: YJV22, YJV23
Certification: ISO, CCC
Model: Yjv22,Yjv23
Brand: Jytop
Trademark: JYTOP
Transport Package: Packed in Reels
Specification: any Third party Pre-shipment inspection
Origin: Zhengzhou, China
HS Code: 8544601200
MIDDLE VOLTAGE 18/30 (33) KV Copper Conductor XLPE Insulated Steel Tape Armored Cable

Mv 18/30kv Copper Conductor XLPE Insulated Steel Tape Armored Power Cable
18/30kV CU/XLPE/STA/PVC(or PE) Power Cable

1. Description
Construction: Compacted stranded circular copper conductor, extruded semi-conducting compound as conductor shield, cross-linked polyethylene (XLPE) insulation, semi-conducting compound as insulation shield, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic polypropylene filler, wrapped with binder tape, PVC inner covering as armoring bedding, double galvanized steel tape armored, PVC or PE outer sheath.

2. Operating Characteristics
Rated voltage U0/U(Um): 18/30(36)kV
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the "highest system voltage" for which the equipment may be used.
Max. Permissible continuous operating temperature of conductor: 90 ° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed: 250 ° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 20 times of the diameter of cable
For three core cable: Not less than 15 times of the diameter of cable

3. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, outdoors, in tunnel or in cable trench, unable to bear external mechanical force.
Single core cable in magnetic duct is not permissible.

4. Manufacturing Standards
IEC 60502-2 and Chinese National Standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.

KINDLY NOTE: If you want to know more details about this kind of products, please visit our website:www.jytopcable.com   for further information.  Thanks.
 
 
Size
Nominal thickness of XLPE insulation(mm) Approx. thickness of copper tape screen (mm) Nominal thickness of steel tape(mm) Nominal thickness of PVC or PE(mm) Approx. overall diameter of finished cable(mm) Max. conductor D.C resistance @ 20ºC(Ω/km)
3x50mm 2 8.0 0.10 0.5 3.2 74.1 0.387
3x70mm 2 8.0 0.10 0.5 3.3 78.1 0.268
3x95mm 2 8.0 0.10 0.5 3.5 82.2 0.193
3x120mm 2 8.0 0.10 0.8 3.6 86.9 0.153
3x150mm 2 8.0 0.10 0.8 3.7 90.6 0.124
3x185mm 2 8.0 0.10 0.8 3.9 94.7 0.0991
3x240mm 2 8.0 0.10 0.8 4.0 100.4 0.0754
3x300mm 2 8.0 0.10 0.8 4.2 105.4 0.0601
3x400mm 2 8.0 0.10 0.8 4.4 113.0 0.0470
MIDDLE VOLTAGE 18/30 (33) KV Copper Conductor XLPE Insulated Steel Tape Armored Cable

Mv 18/30kv Copper Conductor XLPE Insulated Steel Tape Armored Power Cable
18/30kV CU/XLPE/STA/PVC(or PE) Power Cable

1. Description
Construction: Compacted stranded circular copper conductor, extruded semi-conducting compound as conductor shield, cross-linked polyethylene (XLPE) insulation, semi-conducting compound as insulation shield, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic polypropylene filler, wrapped with binder tape, PVC inner covering as armoring bedding, double galvanized steel tape armored, PVC or PE outer sheath.

2. Operating Characteristics
Rated voltage U0/U(Um): 18/30(36)kV
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the "highest system voltage" for which the equipment may be used.
Max. Permissible continuous operating temperature of conductor: 90 ° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed: 250 ° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 20 times of the diameter of cable
For three core cable: Not less than 15 times of the diameter of cable

3. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, outdoors, in tunnel or in cable trench, unable to bear external mechanical force.
Single core cable in magnetic duct is not permissible.

4. Manufacturing Standards
IEC 60502-2 and Chinese National Standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.

KINDLY NOTE: If you want to know more details about this kind of products, please visit our website:www.jytopcable.com   for further information.  Thanks.
 
 
Size
Nominal thickness of XLPE insulation(mm) Approx. thickness of copper tape screen (mm) Nominal thickness of steel tape(mm) Nominal thickness of PVC or PE(mm) Approx. overall diameter of finished cable(mm) Max. conductor D.C resistance @ 20ºC(Ω/km)
3x50mm 2 8.0 0.10 0.5 3.2 74.1 0.387
3x70mm 2 8.0 0.10 0.5 3.3 78.1 0.268
3x95mm 2 8.0 0.10 0.5 3.5 82.2 0.193
3x120mm 2 8.0 0.10 0.8 3.6 86.9 0.153
3x150mm 2 8.0 0.10 0.8 3.7 90.6 0.124
3x185mm 2 8.0 0.10 0.8 3.9 94.7 0.0991
3x240mm 2 8.0 0.10 0.8 4.0 100.4 0.0754
3x300mm 2 8.0 0.10 0.8 4.2 105.4 0.0601
3x400mm 2 8.0 0.10 0.8 4.4 113.0 0.0470

Heat power setting:400/800/1200W        

Automatic tip-off protection          

Oscillating function with handle,easy to be taken

Halogen tube is a sealed light-emitting tube, filled with halogen element inert gas, the middle of the tungsten wire white, black two (due to the cost of white tungsten wire is much higher than the black tungsten wire, so the market is not universal ). Halogen tube with high thermal efficiency, heating is not oxidation, long life and other advantages, and some models also attached to the timing, rotation, humidification and other functions. Halogen tube heater is to rely on luminous heat dissipation, the general use of 2 to 3 halogen tube for the heat source, the power consumption of 900 ~ 1200W or so, more suitable for the area of about 12 square meters of the room, some of the more advanced products with automatic Power, automatic shaking his head and other functions, simple and practical design.

Halogen Heater

Halogen Heater, Electric Halogen Heater, Halogen Room Heater, Portable Halogen Heater

Ningbo APG Machine(appliance)Co.,Ltd , http://www.apgelectrical.com